A calorimetric investigation of doxorubicin-polymer bead interactions

Laura J. Waters, Tanya S. Swaine, Andrew L. Lewis

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

Abstract Isothermal titration calorimetry (ITC) was utilised to investigate suitability of the technique to determine the stoichiometry and thermodynamics of the interactions that occur between a commonly used chemotherapeutic drug, namely doxorubicin, and a polymer bead-based drug delivery embolisation system (DC Bead™). Six temperatures were selected for drug-polymer titrations (293-313 K) and in all cases an initially exothermic signal reverted to an endothermic response upon the saturation of the beads with drug. From these experiments, and subsequent calculations, the molar ratio of drug to SO3 - (polymer) was found to be 0.4:1 at all temperatures studied. Enthalpic data was calculated from the raw ITC data with an average enthalpy of drug-polymer binding of - 14.8 kJ mol-1 at 293 K through to - 19.4 kJ mol-1 at 313 K implying the process is enthalpically-driven yet only affected by an increase in experimental temperature to a limited extent whereby an increase in experimental temperature results in a small increase in the negativity in change in enthalpy recorded. The application of ITC in this study (with its unique ability to monitor real-time interactions and facilitate stoichiometric calculations) resolves the lack of knowledge regarding the thermodynamics of this specific drug-polymer interaction. This study confirms that ITC is not only useful for this specific system, but also highlights the potential use of ITC for more general studies in this area.

Original languageEnglish
Article number15043
Pages (from-to)129-133
Number of pages5
JournalInternational Journal of Pharmaceutics
Volume493
Issue number1-2
DOIs
Publication statusPublished - 4 Aug 2015

Fingerprint

Calorimetry
Doxorubicin
Polymers
Temperature
Pharmaceutical Preparations
Thermodynamics
Drug Delivery Systems
Drug Interactions

Cite this

Waters, Laura J. ; Swaine, Tanya S. ; Lewis, Andrew L. / A calorimetric investigation of doxorubicin-polymer bead interactions. In: International Journal of Pharmaceutics. 2015 ; Vol. 493, No. 1-2. pp. 129-133.
@article{413e37ef9fd1436d80a83a60e2a7c74a,
title = "A calorimetric investigation of doxorubicin-polymer bead interactions",
abstract = "Abstract Isothermal titration calorimetry (ITC) was utilised to investigate suitability of the technique to determine the stoichiometry and thermodynamics of the interactions that occur between a commonly used chemotherapeutic drug, namely doxorubicin, and a polymer bead-based drug delivery embolisation system (DC Bead™). Six temperatures were selected for drug-polymer titrations (293-313 K) and in all cases an initially exothermic signal reverted to an endothermic response upon the saturation of the beads with drug. From these experiments, and subsequent calculations, the molar ratio of drug to SO3 - (polymer) was found to be 0.4:1 at all temperatures studied. Enthalpic data was calculated from the raw ITC data with an average enthalpy of drug-polymer binding of - 14.8 kJ mol-1 at 293 K through to - 19.4 kJ mol-1 at 313 K implying the process is enthalpically-driven yet only affected by an increase in experimental temperature to a limited extent whereby an increase in experimental temperature results in a small increase in the negativity in change in enthalpy recorded. The application of ITC in this study (with its unique ability to monitor real-time interactions and facilitate stoichiometric calculations) resolves the lack of knowledge regarding the thermodynamics of this specific drug-polymer interaction. This study confirms that ITC is not only useful for this specific system, but also highlights the potential use of ITC for more general studies in this area.",
keywords = "Binding, DC Bead™, Doxorubicin, ITC, Polymer, Thermodynamics",
author = "Waters, {Laura J.} and Swaine, {Tanya S.} and Lewis, {Andrew L.}",
year = "2015",
month = "8",
day = "4",
doi = "10.1016/j.ijpharm.2015.07.039",
language = "English",
volume = "493",
pages = "129--133",
journal = "International Journal of Pharmaceutics",
issn = "0378-5173",
publisher = "Elsevier",
number = "1-2",

}

A calorimetric investigation of doxorubicin-polymer bead interactions. / Waters, Laura J.; Swaine, Tanya S.; Lewis, Andrew L.

In: International Journal of Pharmaceutics, Vol. 493, No. 1-2, 15043, 04.08.2015, p. 129-133.

Research output: Contribution to journalArticle

TY - JOUR

T1 - A calorimetric investigation of doxorubicin-polymer bead interactions

AU - Waters, Laura J.

AU - Swaine, Tanya S.

AU - Lewis, Andrew L.

PY - 2015/8/4

Y1 - 2015/8/4

N2 - Abstract Isothermal titration calorimetry (ITC) was utilised to investigate suitability of the technique to determine the stoichiometry and thermodynamics of the interactions that occur between a commonly used chemotherapeutic drug, namely doxorubicin, and a polymer bead-based drug delivery embolisation system (DC Bead™). Six temperatures were selected for drug-polymer titrations (293-313 K) and in all cases an initially exothermic signal reverted to an endothermic response upon the saturation of the beads with drug. From these experiments, and subsequent calculations, the molar ratio of drug to SO3 - (polymer) was found to be 0.4:1 at all temperatures studied. Enthalpic data was calculated from the raw ITC data with an average enthalpy of drug-polymer binding of - 14.8 kJ mol-1 at 293 K through to - 19.4 kJ mol-1 at 313 K implying the process is enthalpically-driven yet only affected by an increase in experimental temperature to a limited extent whereby an increase in experimental temperature results in a small increase in the negativity in change in enthalpy recorded. The application of ITC in this study (with its unique ability to monitor real-time interactions and facilitate stoichiometric calculations) resolves the lack of knowledge regarding the thermodynamics of this specific drug-polymer interaction. This study confirms that ITC is not only useful for this specific system, but also highlights the potential use of ITC for more general studies in this area.

AB - Abstract Isothermal titration calorimetry (ITC) was utilised to investigate suitability of the technique to determine the stoichiometry and thermodynamics of the interactions that occur between a commonly used chemotherapeutic drug, namely doxorubicin, and a polymer bead-based drug delivery embolisation system (DC Bead™). Six temperatures were selected for drug-polymer titrations (293-313 K) and in all cases an initially exothermic signal reverted to an endothermic response upon the saturation of the beads with drug. From these experiments, and subsequent calculations, the molar ratio of drug to SO3 - (polymer) was found to be 0.4:1 at all temperatures studied. Enthalpic data was calculated from the raw ITC data with an average enthalpy of drug-polymer binding of - 14.8 kJ mol-1 at 293 K through to - 19.4 kJ mol-1 at 313 K implying the process is enthalpically-driven yet only affected by an increase in experimental temperature to a limited extent whereby an increase in experimental temperature results in a small increase in the negativity in change in enthalpy recorded. The application of ITC in this study (with its unique ability to monitor real-time interactions and facilitate stoichiometric calculations) resolves the lack of knowledge regarding the thermodynamics of this specific drug-polymer interaction. This study confirms that ITC is not only useful for this specific system, but also highlights the potential use of ITC for more general studies in this area.

KW - Binding

KW - DC Bead™

KW - Doxorubicin

KW - ITC

KW - Polymer

KW - Thermodynamics

UR - http://www.scopus.com/inward/record.url?scp=84938342061&partnerID=8YFLogxK

U2 - 10.1016/j.ijpharm.2015.07.039

DO - 10.1016/j.ijpharm.2015.07.039

M3 - Article

VL - 493

SP - 129

EP - 133

JO - International Journal of Pharmaceutics

JF - International Journal of Pharmaceutics

SN - 0378-5173

IS - 1-2

M1 - 15043

ER -