A holistic calibration method with iterative distortion compensation for stereo deflectometry

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

This paper presents a novel holistic calibration method for stereo deflectometry system to improve the system measurement accuracy. The reconstruction result of stereo deflectometry is integrated with the calculated normal data of the measured surface. The calculation accuracy of the normal data is seriously influenced by the calibration accuracy of the geometrical relationship of the stereo deflectometry system. Conventional calibration approaches introduce form error to the system due to inaccurate imaging model and distortion elimination. The proposed calibration method compensates system distortion based on an iterative algorithm instead of the conventional distortion mathematical model. The initial value of the system parameters are calculated from the fringe patterns displayed on the systemic LCD screen through a reflection of a markless flat mirror. An iterative algorithm is proposed to compensate system distortion and optimize camera imaging parameters and system geometrical relation parameters based on a cost function. Both simulation work and experimental results show the proposed calibration method can significantly improve the calibration and measurement accuracy of a stereo deflectometry. The PV (peak value) of measurement error of a flat mirror can be reduced to 69.7 nm by applying the proposed method from 282 nm obtained with the conventional calibration approach.
Original languageEnglish
Pages (from-to)111-118
Number of pages8
JournalOptics and Lasers in Engineering
Volume106
Early online date7 Mar 2018
DOIs
Publication statusPublished - Jul 2018

Fingerprint

Calibration
mirrors
Mirrors
elimination
mathematical models
diffraction patterns
Imaging techniques
cameras
costs
Compensation and Redress
Measurement errors
Liquid crystal displays
Cost functions
Cameras
Mathematical models
simulation

Cite this

@article{e0bd9317f20f4e44b8c090d56ab55bd1,
title = "A holistic calibration method with iterative distortion compensation for stereo deflectometry",
abstract = "This paper presents a novel holistic calibration method for stereo deflectometry system to improve the system measurement accuracy. The reconstruction result of stereo deflectometry is integrated with the calculated normal data of the measured surface. The calculation accuracy of the normal data is seriously influenced by the calibration accuracy of the geometrical relationship of the stereo deflectometry system. Conventional calibration approaches introduce form error to the system due to inaccurate imaging model and distortion elimination. The proposed calibration method compensates system distortion based on an iterative algorithm instead of the conventional distortion mathematical model. The initial value of the system parameters are calculated from the fringe patterns displayed on the systemic LCD screen through a reflection of a markless flat mirror. An iterative algorithm is proposed to compensate system distortion and optimize camera imaging parameters and system geometrical relation parameters based on a cost function. Both simulation work and experimental results show the proposed calibration method can significantly improve the calibration and measurement accuracy of a stereo deflectometry. The PV (peak value) of measurement error of a flat mirror can be reduced to 69.7 nm by applying the proposed method from 282 nm obtained with the conventional calibration approach.",
keywords = "Algorithms, Calibration, Optical metrology, Phase measurement, Specular surface, Three-dimensional shape measurement",
author = "Yongjia Xu and Feng Gao and Zonghua Zhang and Xiangqian Jiang",
year = "2018",
month = "7",
doi = "10.1016/j.optlaseng.2018.02.018",
language = "English",
volume = "106",
pages = "111--118",
journal = "Optics and Lasers in Engineering",
issn = "0143-8166",
publisher = "Elsevier Limited",

}

TY - JOUR

T1 - A holistic calibration method with iterative distortion compensation for stereo deflectometry

AU - Xu, Yongjia

AU - Gao, Feng

AU - Zhang, Zonghua

AU - Jiang, Xiangqian

PY - 2018/7

Y1 - 2018/7

N2 - This paper presents a novel holistic calibration method for stereo deflectometry system to improve the system measurement accuracy. The reconstruction result of stereo deflectometry is integrated with the calculated normal data of the measured surface. The calculation accuracy of the normal data is seriously influenced by the calibration accuracy of the geometrical relationship of the stereo deflectometry system. Conventional calibration approaches introduce form error to the system due to inaccurate imaging model and distortion elimination. The proposed calibration method compensates system distortion based on an iterative algorithm instead of the conventional distortion mathematical model. The initial value of the system parameters are calculated from the fringe patterns displayed on the systemic LCD screen through a reflection of a markless flat mirror. An iterative algorithm is proposed to compensate system distortion and optimize camera imaging parameters and system geometrical relation parameters based on a cost function. Both simulation work and experimental results show the proposed calibration method can significantly improve the calibration and measurement accuracy of a stereo deflectometry. The PV (peak value) of measurement error of a flat mirror can be reduced to 69.7 nm by applying the proposed method from 282 nm obtained with the conventional calibration approach.

AB - This paper presents a novel holistic calibration method for stereo deflectometry system to improve the system measurement accuracy. The reconstruction result of stereo deflectometry is integrated with the calculated normal data of the measured surface. The calculation accuracy of the normal data is seriously influenced by the calibration accuracy of the geometrical relationship of the stereo deflectometry system. Conventional calibration approaches introduce form error to the system due to inaccurate imaging model and distortion elimination. The proposed calibration method compensates system distortion based on an iterative algorithm instead of the conventional distortion mathematical model. The initial value of the system parameters are calculated from the fringe patterns displayed on the systemic LCD screen through a reflection of a markless flat mirror. An iterative algorithm is proposed to compensate system distortion and optimize camera imaging parameters and system geometrical relation parameters based on a cost function. Both simulation work and experimental results show the proposed calibration method can significantly improve the calibration and measurement accuracy of a stereo deflectometry. The PV (peak value) of measurement error of a flat mirror can be reduced to 69.7 nm by applying the proposed method from 282 nm obtained with the conventional calibration approach.

KW - Algorithms

KW - Calibration

KW - Optical metrology

KW - Phase measurement

KW - Specular surface

KW - Three-dimensional shape measurement

UR - http://www.scopus.com/inward/record.url?scp=85042871129&partnerID=8YFLogxK

U2 - 10.1016/j.optlaseng.2018.02.018

DO - 10.1016/j.optlaseng.2018.02.018

M3 - Article

VL - 106

SP - 111

EP - 118

JO - Optics and Lasers in Engineering

JF - Optics and Lasers in Engineering

SN - 0143-8166