Assessment of absolute partial discharge intensity from a free-space radiometric measurement

A. Jaber, P. Lazaridis, Y. Zhang, B. Saeed, U. Khan, D. Upton, H. Ahmed, P. Mather, M. F Q Vieira, R. Atkinson, M. Judd, I. A. Glover

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

10 Citations (Scopus)

Abstract

Partial discharge (PD) is measured simultaneously using free-space radiometric (FSR) and a galvanic contact measurement technique based on the IEC 60270 standard. The PD source is an emulator of the floating-electrode type. The radiated signal is captured using a biconical antenna. A method of estimating absolute partial discharge (PD) activity level from a radiometric measurement by relating effective radiated power to PD intensity using a PD calibration device is presented.

Original languageEnglish
Title of host publication2016 URSI Asia-Pacific Radio Science Conference, URSI AP-RASC 2016
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages1011-1014
Number of pages4
ISBN (Electronic)9781467388016
DOIs
Publication statusPublished - 20 Oct 2016
Event2016 URSI Asia-Pacific Radio Science Conference - Grand Hilton Seoul Hotel, Seoul, Korea, Republic of
Duration: 21 Aug 201625 Aug 2016
https://www.ursi.org/content/AP-RASC/AP-RASC2016/URSI_AP-RASC_2016_Program.pdf (Link to Conference Programme )

Conference

Conference2016 URSI Asia-Pacific Radio Science Conference
Abbreviated titleURSI AP-RASC 2016
Country/TerritoryKorea, Republic of
CitySeoul
Period21/08/1625/08/16
Internet address

Fingerprint

Dive into the research topics of 'Assessment of absolute partial discharge intensity from a free-space radiometric measurement'. Together they form a unique fingerprint.

Cite this