Abstract
This paper presents a design optimization procedure for high frequency transformer (HFT) employed in bidirectional dual active bridge (DAB) isolated DC-DC converter. It is shown that leakage inductance, phase-shifted angle, skin and proximity effects have to be taken into account together with the HFT voltage-ampere rating to minimize total losses. It is also demonstrated that the leakage inductance required for zero voltage switching operation can be realized under the proposed design procedure without employing extra inductor. The proposed design methodology is experimentally validated by measurements on a prototype HFT.
Original language | English |
---|---|
Title of host publication | Proceedings - 2012 20th International Conference on Electrical Machines, ICEM 2012 |
Publisher | IEEE |
Pages | 2311-2317 |
Number of pages | 7 |
ISBN (Electronic) | 9781467301428, 9781467301411 |
ISBN (Print) | 9781467301435 |
DOIs | |
Publication status | Published - 12 Nov 2012 |
Externally published | Yes |
Event | 20th International Conference on Electrical Machines - Marseille, France Duration: 2 Sep 2012 → 5 Sep 2012 Conference number: 20 |
Conference
Conference | 20th International Conference on Electrical Machines |
---|---|
Abbreviated title | ICEM 2012 |
Country/Territory | France |
City | Marseille |
Period | 2/09/12 → 5/09/12 |