Abstract
This paper presents a digital simulation for a electromagnetic flowmeter which could be used for conducting, low conducting and non-conducting liquids. The digital simulated results show that the low level flow signal could be recovered in the high level background noise associated with the low. or non-conducting liquids if a dual frequency driving and the appropriate digital bandpass filters and phase sensitive detectors are used.
| Original language | English |
|---|---|
| Title of host publication | Proceedings of 2002 IEEE 14th International Conference on Dielectric Liquids |
| Publisher | Institute of Electrical and Electronics Engineers Inc. |
| Pages | 309-311 |
| Number of pages | 3 |
| ISBN (Print) | 0780373502 |
| DOIs | |
| Publication status | Published - 7 Nov 2002 |
| Externally published | Yes |
| Event | 14th International Conference on Dielectric Liquids - Graz, Austria Duration: 7 Jul 2002 → 12 Jul 2002 Conference number: 14 |
Conference
| Conference | 14th International Conference on Dielectric Liquids |
|---|---|
| Abbreviated title | ICDL 2002 |
| Country/Territory | Austria |
| City | Graz |
| Period | 7/07/02 → 12/07/02 |