Fluorescence-detected magnetic field effects on radical pair reactions from femtolitre volumes

C. A. Dodson, C. J. Wedge, M. Murakami, K. Maeda, M. I. Wallace, P. J. Hore

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

We show that the effects of applied magnetic fields on radical pair reactions can be sensitively measured from sample volumes as low as ∼100 femtolitres using total internal reflection fluorescence microscopy. Development of a fluorescence-based microscope method is likely to be a key step in further miniaturisation that will allow detection of magnetic field effects on single molecules.

LanguageEnglish
Pages8023-8026
Number of pages4
JournalChemical Communications
Volume51
Issue number38
DOIs
Publication statusPublished - 25 Mar 2015
Externally publishedYes

Fingerprint

Magnetic field effects
Fluorescence microscopy
Magnetic Fields
Microscopes
Fluorescence
Magnetic fields
Miniaturization
Molecules
Fluorescence Microscopy

Cite this

Dodson, C. A. ; Wedge, C. J. ; Murakami, M. ; Maeda, K. ; Wallace, M. I. ; Hore, P. J. / Fluorescence-detected magnetic field effects on radical pair reactions from femtolitre volumes. In: Chemical Communications. 2015 ; Vol. 51, No. 38. pp. 8023-8026.
@article{cfb29d668eed43ef81d8042de62737ae,
title = "Fluorescence-detected magnetic field effects on radical pair reactions from femtolitre volumes",
abstract = "We show that the effects of applied magnetic fields on radical pair reactions can be sensitively measured from sample volumes as low as ∼100 femtolitres using total internal reflection fluorescence microscopy. Development of a fluorescence-based microscope method is likely to be a key step in further miniaturisation that will allow detection of magnetic field effects on single molecules.",
author = "Dodson, {C. A.} and Wedge, {C. J.} and M. Murakami and K. Maeda and Wallace, {M. I.} and Hore, {P. J.}",
year = "2015",
month = "3",
day = "25",
doi = "10.1039/c5cc01099c",
language = "English",
volume = "51",
pages = "8023--8026",
journal = "Chemical Communications",
issn = "1359-7345",
publisher = "Royal Society of Chemistry",
number = "38",

}

Fluorescence-detected magnetic field effects on radical pair reactions from femtolitre volumes. / Dodson, C. A.; Wedge, C. J.; Murakami, M.; Maeda, K.; Wallace, M. I.; Hore, P. J.

In: Chemical Communications, Vol. 51, No. 38, 25.03.2015, p. 8023-8026.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Fluorescence-detected magnetic field effects on radical pair reactions from femtolitre volumes

AU - Dodson, C. A.

AU - Wedge, C. J.

AU - Murakami, M.

AU - Maeda, K.

AU - Wallace, M. I.

AU - Hore, P. J.

PY - 2015/3/25

Y1 - 2015/3/25

N2 - We show that the effects of applied magnetic fields on radical pair reactions can be sensitively measured from sample volumes as low as ∼100 femtolitres using total internal reflection fluorescence microscopy. Development of a fluorescence-based microscope method is likely to be a key step in further miniaturisation that will allow detection of magnetic field effects on single molecules.

AB - We show that the effects of applied magnetic fields on radical pair reactions can be sensitively measured from sample volumes as low as ∼100 femtolitres using total internal reflection fluorescence microscopy. Development of a fluorescence-based microscope method is likely to be a key step in further miniaturisation that will allow detection of magnetic field effects on single molecules.

UR - http://www.scopus.com/inward/record.url?scp=84928978417&partnerID=8YFLogxK

U2 - 10.1039/c5cc01099c

DO - 10.1039/c5cc01099c

M3 - Article

VL - 51

SP - 8023

EP - 8026

JO - Chemical Communications

T2 - Chemical Communications

JF - Chemical Communications

SN - 1359-7345

IS - 38

ER -