Abstract
In this work, we investigated the degradation of commercial camera sensors exposed to 100 Gy of γ dose at dose rates of 0.55 Gy/min and 1.34 Gy/min respectively. The results show that the degradation is strongly dependent on the dose rate but doesnt vary much with the accumulation of dose at constant dose rate. Furthermore, cameras with in-built processing electronics are more susceptible to gamma radiations as compared to the cameras with sensing unit only.
Original language | English |
---|---|
Title of host publication | 2019 IEEE Sensors, SENSORS 2019 - Conference Proceedings |
Publisher | IEEE |
Number of pages | 4 |
ISBN (Electronic) | 9781728116341 |
ISBN (Print) | 9781728116358 |
DOIs | |
Publication status | Published - 27 Oct 2019 |
Externally published | Yes |
Event | 18th IEEE Sensors - Montreal, Canada Duration: 27 Oct 2019 → 30 Oct 2019 Conference number: 18 |
Publication series
Name | Proceedings of IEEE Sensors |
---|---|
Volume | 2019-October |
ISSN (Print) | 1930-0395 |
ISSN (Electronic) | 2168-9229 |
Conference
Conference | 18th IEEE Sensors |
---|---|
Abbreviated title | SENSORS 2019 |
Country/Territory | Canada |
City | Montreal |
Period | 27/10/19 → 30/10/19 |