T1 - Gated Pipelined Folding ADC based Low Power Sensor for Large-Scale Radiometric Partial Discharge Monitoring
AU - Upton, David
AU - Haigh, Richard
AU - Mather, Peter
AU - Lazaridis, Pavlos
AU - Mistry, Keyur
AU - Zaharis, Zaharias
AU - Tachtatzis, Christos
AU - Atkinson, Robert
N1 - UKRI EPSRC Grant number: EP/J015873/1
PY - 2020/7/15
Y1 - 2020/7/15
N2 - Partial discharge is a well-established metric for condition assessment of high-voltage plant equipment. Traditional techniques for partial discharge detection involve physical connection of sensors to the device under observation, limiting sensors to monitoring of individual apparatus, and therefore, limiting coverage. Wireless measurement provides an attractive low-cost alternative. The measurement of the radiometric signal propagated from a partial discharge source allows for multiple plant items to be observed by a single sensor, without any physical connection to the plant. Moreover, the implementation of a large-scale wireless sensor network for radiometric monitoring facilitates a simple approach to high voltage fault diagnostics. However, accurate measurement typically requires fast data conversion rates to ensure accurate measurement of faults. The use of high-speed conversion requires continuous high-power dissipation, degrading sensor efficiency and increasing cost and complexity. Thus, we propose a radiometric sensor which utilizes a gated, pipelined, sample-and-hold based folding analogue-to-digital converter structure that only samples when a signal is received, reducing the power consumption and increasing the efficiency of the sensor. A proof of concept circuit has been developed using discrete components to evaluate the performance and power consumption of the system.
AB - Partial discharge is a well-established metric for condition assessment of high-voltage plant equipment. Traditional techniques for partial discharge detection involve physical connection of sensors to the device under observation, limiting sensors to monitoring of individual apparatus, and therefore, limiting coverage. Wireless measurement provides an attractive low-cost alternative. The measurement of the radiometric signal propagated from a partial discharge source allows for multiple plant items to be observed by a single sensor, without any physical connection to the plant. Moreover, the implementation of a large-scale wireless sensor network for radiometric monitoring facilitates a simple approach to high voltage fault diagnostics. However, accurate measurement typically requires fast data conversion rates to ensure accurate measurement of faults. The use of high-speed conversion requires continuous high-power dissipation, degrading sensor efficiency and increasing cost and complexity. Thus, we propose a radiometric sensor which utilizes a gated, pipelined, sample-and-hold based folding analogue-to-digital converter structure that only samples when a signal is received, reducing the power consumption and increasing the efficiency of the sensor. A proof of concept circuit has been developed using discrete components to evaluate the performance and power consumption of the system.
KW - Analog-digital conversion
KW - Partial discharge measurement
KW - Radiometers
KW - UHF measurements
KW - Wireless sensor networks
UR - http://www.scopus.com/inward/record.url?scp=85088026475&partnerID=8YFLogxK
U2 - 10.1109/JSEN.2020.2982576
DO - 10.1109/JSEN.2020.2982576
M3 - Article
VL - 20
SP - 7826
EP - 7836
JO - IEEE Sensors Journal
JF - IEEE Sensors Journal
SN - 1530-437X
IS - 14
M1 - 9044435