Interfacial friction in upward annular gas–liquid two-phase flow in pipes

Aliyu Musa Aliyu, Yahaya Danjuma Baba, Liyun Lao, Hoi Yeung, Kyung Chun Kim

Research output: Contribution to journalArticle

20 Citations (Scopus)

Abstract

Accurate prediction of interfacial friction between the gas and liquid in annular two-phase flow in pipes is essential for the proper modelling of pressure drop and heat transfer coefficient in pipeline systems. Many empirical relationships have been obtained over the last half century. However, they are restricted to limited superficial liquid and gas velocity ranges, essentially apply to atmospheric pressures, and the relationships are only relevant for pipes with inner diameters between 10 and 50 mm. In this study, we carried out experiments in a large diameter flow loop of 101.6 mm internal diameter with the superficial gas and liquid ranges of 11–29 m/s and 0.1–1.0 m/s respectively. An examination of published interfacial friction factor correlations was carried out using a diverse database which was collected from the open literature for vertical annular flow. The database includes measurements in pipes of 16–127 mm inner diameter for the liquid film thickness, interfacial shear stress, and pressure gradient for air-water, air-water/glycerol, and argon-water flows. Eleven studies are represented with experimental pressures of up to 6 bar. Significant discrepancies were found between many of the published correlations and the large pipe data, primarily in the thick film region at low interfacial shear stress. A correlation for the interfacial friction factor was hence derived using the extensive database. The correlation includes dimensionless numbers for the effect of the diameter across pipe scales to be better represented and better fit the wide range of experimental conditions, fluid properties, and operating pressures.

Original languageEnglish
Pages (from-to)90-109
Number of pages20
JournalExperimental Thermal and Fluid Science
Volume84
Early online date7 Feb 2017
DOIs
Publication statusPublished - 1 Jun 2017
Externally publishedYes

Fingerprint

Two phase flow
Pipe
Friction
Gases
Water
Shear stress
Liquids
Argon
Liquid films
Air
Pressure gradient
Glycerol
Thick films
Heat transfer coefficients
Atmospheric pressure
Pressure drop
Film thickness
Pipelines
Fluids
Experiments

Cite this

Aliyu, Aliyu Musa ; Baba, Yahaya Danjuma ; Lao, Liyun ; Yeung, Hoi ; Kim, Kyung Chun. / Interfacial friction in upward annular gas–liquid two-phase flow in pipes. In: Experimental Thermal and Fluid Science. 2017 ; Vol. 84. pp. 90-109.
@article{cc779fbfecd44ec6bcff674ea7928b94,
title = "Interfacial friction in upward annular gas–liquid two-phase flow in pipes",
abstract = "Accurate prediction of interfacial friction between the gas and liquid in annular two-phase flow in pipes is essential for the proper modelling of pressure drop and heat transfer coefficient in pipeline systems. Many empirical relationships have been obtained over the last half century. However, they are restricted to limited superficial liquid and gas velocity ranges, essentially apply to atmospheric pressures, and the relationships are only relevant for pipes with inner diameters between 10 and 50 mm. In this study, we carried out experiments in a large diameter flow loop of 101.6 mm internal diameter with the superficial gas and liquid ranges of 11–29 m/s and 0.1–1.0 m/s respectively. An examination of published interfacial friction factor correlations was carried out using a diverse database which was collected from the open literature for vertical annular flow. The database includes measurements in pipes of 16–127 mm inner diameter for the liquid film thickness, interfacial shear stress, and pressure gradient for air-water, air-water/glycerol, and argon-water flows. Eleven studies are represented with experimental pressures of up to 6 bar. Significant discrepancies were found between many of the published correlations and the large pipe data, primarily in the thick film region at low interfacial shear stress. A correlation for the interfacial friction factor was hence derived using the extensive database. The correlation includes dimensionless numbers for the effect of the diameter across pipe scales to be better represented and better fit the wide range of experimental conditions, fluid properties, and operating pressures.",
keywords = "Co-current annular flow, Interfacial shear stress, Liquid film thickness, Pressure gradient, Vertical two-phase flow",
author = "Aliyu, {Aliyu Musa} and Baba, {Yahaya Danjuma} and Liyun Lao and Hoi Yeung and Kim, {Kyung Chun}",
year = "2017",
month = "6",
day = "1",
doi = "10.1016/j.expthermflusci.2017.02.006",
language = "English",
volume = "84",
pages = "90--109",
journal = "Experimental Thermal and Fluid Science",
issn = "0894-1777",
publisher = "Elsevier",

}

Interfacial friction in upward annular gas–liquid two-phase flow in pipes. / Aliyu, Aliyu Musa; Baba, Yahaya Danjuma; Lao, Liyun; Yeung, Hoi; Kim, Kyung Chun.

In: Experimental Thermal and Fluid Science, Vol. 84, 01.06.2017, p. 90-109.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Interfacial friction in upward annular gas–liquid two-phase flow in pipes

AU - Aliyu, Aliyu Musa

AU - Baba, Yahaya Danjuma

AU - Lao, Liyun

AU - Yeung, Hoi

AU - Kim, Kyung Chun

PY - 2017/6/1

Y1 - 2017/6/1

N2 - Accurate prediction of interfacial friction between the gas and liquid in annular two-phase flow in pipes is essential for the proper modelling of pressure drop and heat transfer coefficient in pipeline systems. Many empirical relationships have been obtained over the last half century. However, they are restricted to limited superficial liquid and gas velocity ranges, essentially apply to atmospheric pressures, and the relationships are only relevant for pipes with inner diameters between 10 and 50 mm. In this study, we carried out experiments in a large diameter flow loop of 101.6 mm internal diameter with the superficial gas and liquid ranges of 11–29 m/s and 0.1–1.0 m/s respectively. An examination of published interfacial friction factor correlations was carried out using a diverse database which was collected from the open literature for vertical annular flow. The database includes measurements in pipes of 16–127 mm inner diameter for the liquid film thickness, interfacial shear stress, and pressure gradient for air-water, air-water/glycerol, and argon-water flows. Eleven studies are represented with experimental pressures of up to 6 bar. Significant discrepancies were found between many of the published correlations and the large pipe data, primarily in the thick film region at low interfacial shear stress. A correlation for the interfacial friction factor was hence derived using the extensive database. The correlation includes dimensionless numbers for the effect of the diameter across pipe scales to be better represented and better fit the wide range of experimental conditions, fluid properties, and operating pressures.

AB - Accurate prediction of interfacial friction between the gas and liquid in annular two-phase flow in pipes is essential for the proper modelling of pressure drop and heat transfer coefficient in pipeline systems. Many empirical relationships have been obtained over the last half century. However, they are restricted to limited superficial liquid and gas velocity ranges, essentially apply to atmospheric pressures, and the relationships are only relevant for pipes with inner diameters between 10 and 50 mm. In this study, we carried out experiments in a large diameter flow loop of 101.6 mm internal diameter with the superficial gas and liquid ranges of 11–29 m/s and 0.1–1.0 m/s respectively. An examination of published interfacial friction factor correlations was carried out using a diverse database which was collected from the open literature for vertical annular flow. The database includes measurements in pipes of 16–127 mm inner diameter for the liquid film thickness, interfacial shear stress, and pressure gradient for air-water, air-water/glycerol, and argon-water flows. Eleven studies are represented with experimental pressures of up to 6 bar. Significant discrepancies were found between many of the published correlations and the large pipe data, primarily in the thick film region at low interfacial shear stress. A correlation for the interfacial friction factor was hence derived using the extensive database. The correlation includes dimensionless numbers for the effect of the diameter across pipe scales to be better represented and better fit the wide range of experimental conditions, fluid properties, and operating pressures.

KW - Co-current annular flow

KW - Interfacial shear stress

KW - Liquid film thickness

KW - Pressure gradient

KW - Vertical two-phase flow

UR - http://www.scopus.com/inward/record.url?scp=85013177914&partnerID=8YFLogxK

U2 - 10.1016/j.expthermflusci.2017.02.006

DO - 10.1016/j.expthermflusci.2017.02.006

M3 - Article

AN - SCOPUS:85013177914

VL - 84

SP - 90

EP - 109

JO - Experimental Thermal and Fluid Science

JF - Experimental Thermal and Fluid Science

SN - 0894-1777

ER -