An accurate system calibration method is presented in this paper to calibrate stereo deflectometry. A corresponding iterative optimization algorithm is also proposed to improve the system calibration accuracy. This merges CCD parameters and geometrical relation between CCDs and the LCD into one cost function. In this calibration technique, an optical flat acts as a reference mirror and simultaneously reflect sinusoidal fringe patterns into the two CCDs. The normal vector of the reference mirror is used as an intermediate variable to implement this iterative optimization algorithm until the root mean square of the reprojection errors converge to a minimum. The experiment demonstrates that this method can optimize all the calibration parameters and can effectively reduce reprojection error, which correspondingly improves the final reconstruction accuracy.

Original languageEnglish
Pages (from-to)2260-22068
Number of pages19809
JournalOptics Express
Volume23
Issue number17
DOIs
Publication statusPublished - 24 Aug 2015

Fingerprint

charge coupled devices
optimization
mirrors
diffraction patterns
costs

Cite this

@article{b45d7be0cf7d46738056f41273f452b8,
title = "Iterative optimization calibration method for stereo deflectometry",
abstract = "An accurate system calibration method is presented in this paper to calibrate stereo deflectometry. A corresponding iterative optimization algorithm is also proposed to improve the system calibration accuracy. This merges CCD parameters and geometrical relation between CCDs and the LCD into one cost function. In this calibration technique, an optical flat acts as a reference mirror and simultaneously reflect sinusoidal fringe patterns into the two CCDs. The normal vector of the reference mirror is used as an intermediate variable to implement this iterative optimization algorithm until the root mean square of the reprojection errors converge to a minimum. The experiment demonstrates that this method can optimize all the calibration parameters and can effectively reduce reprojection error, which correspondingly improves the final reconstruction accuracy.",
author = "Hongyu Ren and Feng Gao and Xiangqian Jiang",
year = "2015",
month = "8",
day = "24",
doi = "10.1364/OE.23.022060",
language = "English",
volume = "23",
pages = "2260--22068",
journal = "Optics Express",
issn = "1094-4087",
publisher = "The Optical Society",
number = "17",

}

Iterative optimization calibration method for stereo deflectometry. / Ren, Hongyu; Gao, Feng; Jiang, Xiangqian.

In: Optics Express, Vol. 23, No. 17, 24.08.2015, p. 2260-22068.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Iterative optimization calibration method for stereo deflectometry

AU - Ren, Hongyu

AU - Gao, Feng

AU - Jiang, Xiangqian

PY - 2015/8/24

Y1 - 2015/8/24

N2 - An accurate system calibration method is presented in this paper to calibrate stereo deflectometry. A corresponding iterative optimization algorithm is also proposed to improve the system calibration accuracy. This merges CCD parameters and geometrical relation between CCDs and the LCD into one cost function. In this calibration technique, an optical flat acts as a reference mirror and simultaneously reflect sinusoidal fringe patterns into the two CCDs. The normal vector of the reference mirror is used as an intermediate variable to implement this iterative optimization algorithm until the root mean square of the reprojection errors converge to a minimum. The experiment demonstrates that this method can optimize all the calibration parameters and can effectively reduce reprojection error, which correspondingly improves the final reconstruction accuracy.

AB - An accurate system calibration method is presented in this paper to calibrate stereo deflectometry. A corresponding iterative optimization algorithm is also proposed to improve the system calibration accuracy. This merges CCD parameters and geometrical relation between CCDs and the LCD into one cost function. In this calibration technique, an optical flat acts as a reference mirror and simultaneously reflect sinusoidal fringe patterns into the two CCDs. The normal vector of the reference mirror is used as an intermediate variable to implement this iterative optimization algorithm until the root mean square of the reprojection errors converge to a minimum. The experiment demonstrates that this method can optimize all the calibration parameters and can effectively reduce reprojection error, which correspondingly improves the final reconstruction accuracy.

UR - http://www.scopus.com/inward/record.url?scp=84957584988&partnerID=8YFLogxK

U2 - 10.1364/OE.23.022060

DO - 10.1364/OE.23.022060

M3 - Article

VL - 23

SP - 2260

EP - 22068

JO - Optics Express

JF - Optics Express

SN - 1094-4087

IS - 17

ER -