The term partial discharge (PD) refers to a partial breakdown in an insulator which bridges two conductors.PD occurs due to insulation defects which arise as a result of high voltage stresses or insulation cracks. Continuous monitoring of PD activity can have a significant impact towards mitigating catastrophic failures. In recent times, it has become possible to detect and locate a PD activity on an automated basis using wireless sensor technology. In this paper, a novel technique for PD detection and localization using a wireless sensor network (WSN) is presented. The localization algorithm is based on received signal strength (RSS).
Original languageEnglish
Title of host publication2nd URSI Atlantic Radio Science Conference Proceedings
PublisherInstitute of Electrical and Electronics Engineers Inc.
Number of pages4
ISBN (Electronic)9789082598735
ISBN (Print)9781538637647
DOIs
Publication statusPublished - 27 Sep 2018
Event2nd International Union of Radio Science Atlantic Radio Science Conference - ExpoMeloneras Convention Centre, Gran Canaria, Spain
Duration: 28 May 20181 Jun 2018
Conference number: 2
http://www.atrasc.com/callforpapers.php (Link to Call for Papers)

Conference

Conference2nd International Union of Radio Science Atlantic Radio Science Conference
Abbreviated titleURSI AT-RASC 2018
CountrySpain
CityGran Canaria
Period28/05/181/06/18
Internet address

Fingerprint

Partial discharges
Insulation
Wireless sensor networks
Cracks
Defects
Monitoring
Sensors
Electric potential

Cite this

Khan, U., Lazaridis, P., Mohamed, H., Upton, D., Mistry, K., Saeed, B., ... Glover, I. (2018). Localization of Partial Discharge by Using Received Signal Strength. In 2nd URSI Atlantic Radio Science Conference Proceedings Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.23919/URSI-AT-RASC.2018.8471320
Khan, Umar ; Lazaridis, Pavlos ; Mohamed, Hamd ; Upton, David ; Mistry, Keyur ; Saeed, Bahghtar ; Mather, Peter ; Vieira, Maria De Fatima Queiroz ; Atkinson, Robert ; Tachtatzis, Christos ; Glover, Ian. / Localization of Partial Discharge by Using Received Signal Strength. 2nd URSI Atlantic Radio Science Conference Proceedings. Institute of Electrical and Electronics Engineers Inc., 2018.
@inproceedings{987d08d0e4ac4fe7a5876bc6f60a7dcb,
title = "Localization of Partial Discharge by Using Received Signal Strength",
abstract = "The term partial discharge (PD) refers to a partial breakdown in an insulator which bridges two conductors.PD occurs due to insulation defects which arise as a result of high voltage stresses or insulation cracks. Continuous monitoring of PD activity can have a significant impact towards mitigating catastrophic failures. In recent times, it has become possible to detect and locate a PD activity on an automated basis using wireless sensor technology. In this paper, a novel technique for PD detection and localization using a wireless sensor network (WSN) is presented. The localization algorithm is based on received signal strength (RSS).",
keywords = "VHF, WSN, Localizatio, Partial discharge, RSS, UHF",
author = "Umar Khan and Pavlos Lazaridis and Hamd Mohamed and David Upton and Keyur Mistry and Bahghtar Saeed and Peter Mather and Vieira, {Maria De Fatima Queiroz} and Robert Atkinson and Christos Tachtatzis and Ian Glover",
note = "{\circledC} 2018 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.",
year = "2018",
month = "9",
day = "27",
doi = "10.23919/URSI-AT-RASC.2018.8471320",
language = "English",
isbn = "9781538637647",
booktitle = "2nd URSI Atlantic Radio Science Conference Proceedings",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

Khan, U, Lazaridis, P, Mohamed, H, Upton, D, Mistry, K, Saeed, B, Mather, P, Vieira, MDFQ, Atkinson, R, Tachtatzis, C & Glover, I 2018, Localization of Partial Discharge by Using Received Signal Strength. in 2nd URSI Atlantic Radio Science Conference Proceedings. Institute of Electrical and Electronics Engineers Inc., 2nd International Union of Radio Science Atlantic Radio Science Conference, Gran Canaria, Spain, 28/05/18. https://doi.org/10.23919/URSI-AT-RASC.2018.8471320

Localization of Partial Discharge by Using Received Signal Strength. / Khan, Umar; Lazaridis, Pavlos; Mohamed, Hamd; Upton, David; Mistry, Keyur; Saeed, Bahghtar; Mather, Peter; Vieira, Maria De Fatima Queiroz; Atkinson, Robert; Tachtatzis, Christos; Glover, Ian.

2nd URSI Atlantic Radio Science Conference Proceedings. Institute of Electrical and Electronics Engineers Inc., 2018.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

TY - GEN

T1 - Localization of Partial Discharge by Using Received Signal Strength

AU - Khan, Umar

AU - Lazaridis, Pavlos

AU - Mohamed, Hamd

AU - Upton, David

AU - Mistry, Keyur

AU - Saeed, Bahghtar

AU - Mather, Peter

AU - Vieira, Maria De Fatima Queiroz

AU - Atkinson, Robert

AU - Tachtatzis, Christos

AU - Glover, Ian

N1 - © 2018 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.

PY - 2018/9/27

Y1 - 2018/9/27

N2 - The term partial discharge (PD) refers to a partial breakdown in an insulator which bridges two conductors.PD occurs due to insulation defects which arise as a result of high voltage stresses or insulation cracks. Continuous monitoring of PD activity can have a significant impact towards mitigating catastrophic failures. In recent times, it has become possible to detect and locate a PD activity on an automated basis using wireless sensor technology. In this paper, a novel technique for PD detection and localization using a wireless sensor network (WSN) is presented. The localization algorithm is based on received signal strength (RSS).

AB - The term partial discharge (PD) refers to a partial breakdown in an insulator which bridges two conductors.PD occurs due to insulation defects which arise as a result of high voltage stresses or insulation cracks. Continuous monitoring of PD activity can have a significant impact towards mitigating catastrophic failures. In recent times, it has become possible to detect and locate a PD activity on an automated basis using wireless sensor technology. In this paper, a novel technique for PD detection and localization using a wireless sensor network (WSN) is presented. The localization algorithm is based on received signal strength (RSS).

KW - VHF

KW - WSN

KW - Localizatio

KW - Partial discharge

KW - RSS

KW - UHF

U2 - 10.23919/URSI-AT-RASC.2018.8471320

DO - 10.23919/URSI-AT-RASC.2018.8471320

M3 - Conference contribution

SN - 9781538637647

BT - 2nd URSI Atlantic Radio Science Conference Proceedings

PB - Institute of Electrical and Electronics Engineers Inc.

ER -

Khan U, Lazaridis P, Mohamed H, Upton D, Mistry K, Saeed B et al. Localization of Partial Discharge by Using Received Signal Strength. In 2nd URSI Atlantic Radio Science Conference Proceedings. Institute of Electrical and Electronics Engineers Inc. 2018 https://doi.org/10.23919/URSI-AT-RASC.2018.8471320