TY - JOUR
T1 - Monitoring and modelling of indoor environmental quality to guide indoor greening applications
AU - Kumar, Prashant
AU - Valentim Goulart, Elisa
AU - Sun, Hao
AU - Kaiser Calautit, John
AU - Corada Pérez, Karina
AU - Song, Wenjie
AU - Giulia Linnea Persiani, Sandra
AU - Bhui, Kamaldeep
AU - Booker, Douglas
AU - Considine, Brian
AU - Fatahian, Hossein
AU - Fraga, Bruño
AU - Furieri, Bruno
AU - Huang, Yuhan
AU - Irga, Peter J.
AU - Jones, Laurence
AU - Kulshreshtha, Priyanka
AU - K. Luhar, Ashok
AU - Lo laconno, Giovanni
AU - Clara Vieira Martins Starling, Maria
AU - McNabola, Aonghus
AU - Mishra, Rakesh
AU - Morawska, Lidia
AU - A Nasir, Zaheer
AU - O’Donnell, James
AU - Omidvarborna, Hamid
AU - Pfrang, Christian
AU - Rajagopalan, Priya
AU - Costa Reis Junior, Neyval
AU - Schofield, Robyn
AU - Meri Santos, Jane
AU - Silva Galvão, Elson
AU - Sood, Divyanshu
AU - Toledo de Almeida Albuquerque, Taciana
AU - Wenk, Jannis
PY - 2026/11/10
Y1 - 2026/11/10
N2 - Indoor green infrastructures (iGI) can improve indoor environmental quality (IEQ), but inconsistent quantification methods undermine confidence in reported benefits and limit evidence-based design. This review synthesises monitoring and modelling methods to assess iGI impacts on IEQ, including outdoor-indoor interactions and climate change effects. Sixty studies were reviewed covering passive (potted plants, green walls, and indoor trees) and active (hydroponics, biofilters) systems. Both improve IEQ, with varying outcomes depending on configuration and environmental conditions. Passive systems, dominated by potted plants and green walls, demonstrate VOC reduction (typically 10%–30%) and help regulate temperature and humidity, while active systems achieve superior removal efficiencies for VOCs and particulate matter. The literature skews toward laboratory studies (59%) versus in-situ monitoring (33%). Many studies rely on short-duration chamber experiments (<1 m³ over; 6–48 h). Controlled settings report higher pollutant removal than real buildings, complicated by non-standardised iGI descriptors and ventilation data. Studies focus on a few plant taxa (Chlorophytum, Philodendron, Epipremnum, Spathiphyllum), measuring primarily temperature, humidity, and CO₂. Modelling is context-specific, mainly targeting hygrothermal and CO₂ processes in wall systems. Impacts depend on ventilation, lighting and greening intensity, with passive configurations reducing cooling demand by 22%–27% and low-light conditions weakening CO₂ uptake [about 25 to 70 μmol/(m²∙s) PAR]. Outdoor–indoor interaction studies remain rare and poorly quantified. Few address future climate scenarios, creating uncertainty about benefits versus risks of elevated humidity, condensation/mould, and pollutant re-emission. Current practices inadequately attribute IEQ impacts to iGI interventions. Advancement requires standardised reporting protocols, integrated monitoring-modelling, explicit outdoor–indoor coupling, and climate-aware assessments with defined uncertainty boundaries.
AB - Indoor green infrastructures (iGI) can improve indoor environmental quality (IEQ), but inconsistent quantification methods undermine confidence in reported benefits and limit evidence-based design. This review synthesises monitoring and modelling methods to assess iGI impacts on IEQ, including outdoor-indoor interactions and climate change effects. Sixty studies were reviewed covering passive (potted plants, green walls, and indoor trees) and active (hydroponics, biofilters) systems. Both improve IEQ, with varying outcomes depending on configuration and environmental conditions. Passive systems, dominated by potted plants and green walls, demonstrate VOC reduction (typically 10%–30%) and help regulate temperature and humidity, while active systems achieve superior removal efficiencies for VOCs and particulate matter. The literature skews toward laboratory studies (59%) versus in-situ monitoring (33%). Many studies rely on short-duration chamber experiments (<1 m³ over; 6–48 h). Controlled settings report higher pollutant removal than real buildings, complicated by non-standardised iGI descriptors and ventilation data. Studies focus on a few plant taxa (Chlorophytum, Philodendron, Epipremnum, Spathiphyllum), measuring primarily temperature, humidity, and CO₂. Modelling is context-specific, mainly targeting hygrothermal and CO₂ processes in wall systems. Impacts depend on ventilation, lighting and greening intensity, with passive configurations reducing cooling demand by 22%–27% and low-light conditions weakening CO₂ uptake [about 25 to 70 μmol/(m²∙s) PAR]. Outdoor–indoor interaction studies remain rare and poorly quantified. Few address future climate scenarios, creating uncertainty about benefits versus risks of elevated humidity, condensation/mould, and pollutant re-emission. Current practices inadequately attribute IEQ impacts to iGI interventions. Advancement requires standardised reporting protocols, integrated monitoring-modelling, explicit outdoor–indoor coupling, and climate-aware assessments with defined uncertainty boundaries.
KW - Indoor green infrastructure
KW - Building performance
KW - Monitoring and modelling
KW - Indoor-outdoor coupling
KW - Climate change
KW - Sustainable Development Goals
U2 - 10.1016/j.eehl.2026.100289
DO - 10.1016/j.eehl.2026.100289
M3 - Review article
SN - 2772-9850
VL - 5
JO - Eco-Environment and Health
JF - Eco-Environment and Health
IS - 4
M1 - 100289
ER -