Skip to main navigation Skip to search Skip to main content

Monitoring and modelling of indoor environmental quality to guide indoor greening applications

Prashant Kumar, Elisa Valentim Goulart, Hao Sun, John Kaiser Calautit, Karina Corada Pérez, Wenjie Song, Sandra Giulia Linnea Persiani, Kamaldeep Bhui, Douglas Booker, Brian Considine, Hossein Fatahian, Bruño Fraga, Bruno Furieri, Yuhan Huang, Peter J. Irga, Laurence Jones, Priyanka Kulshreshtha, Ashok K. Luhar, Giovanni Lo laconno, Maria Clara Vieira Martins StarlingAonghus McNabola, Rakesh Mishra, Lidia Morawska, Zaheer A Nasir, James O’Donnell, Hamid Omidvarborna, Christian Pfrang, Priya Rajagopalan, Neyval Costa Reis Junior, Robyn Schofield, Jane Meri Santos, Elson Silva Galvão, Divyanshu Sood, Taciana Toledo de Almeida Albuquerque, Jannis Wenk

Research output: Contribution to journal › Review article › peer-review

Abstract

Indoor green infrastructures (iGI) can improve indoor environmental quality (IEQ), but inconsistent quantification methods undermine confidence in reported benefits and limit evidence-based design. This review synthesises monitoring and modelling methods to assess iGI impacts on IEQ, including outdoor-indoor interactions and climate change effects. Sixty studies were reviewed covering passive (potted plants, green walls, and indoor trees) and active (hydroponics, biofilters) systems. Both improve IEQ, with varying outcomes depending on configuration and environmental conditions. Passive systems, dominated by potted plants and green walls, demonstrate VOC reduction (typically 10%–30%) and help regulate temperature and humidity, while active systems achieve superior removal efficiencies for VOCs and particulate matter. The literature skews toward laboratory studies (59%) versus in-situ monitoring (33%). Many studies rely on short-duration chamber experiments (<1 m³ over; 6–48 h). Controlled settings report higher pollutant removal than real buildings, complicated by non-standardised iGI descriptors and ventilation data. Studies focus on a few plant taxa (Chlorophytum, Philodendron, Epipremnum, Spathiphyllum), measuring primarily temperature, humidity, and CO₂. Modelling is context-specific, mainly targeting hygrothermal and CO₂ processes in wall systems. Impacts depend on ventilation, lighting and greening intensity, with passive configurations reducing cooling demand by 22%–27% and low-light conditions weakening CO₂ uptake [about 25 to 70 μmol/(m²∙s) PAR]. Outdoor–indoor interaction studies remain rare and poorly quantified. Few address future climate scenarios, creating uncertainty about benefits versus risks of elevated humidity, condensation/mould, and pollutant re-emission. Current practices inadequately attribute IEQ impacts to iGI interventions. Advancement requires standardised reporting protocols, integrated monitoring-modelling, explicit outdoor–indoor coupling, and climate-aware assessments with defined uncertainty boundaries.
Original languageEnglish
Article number100289
Number of pages20
JournalEco-Environment and Health
Volume5
Issue number4
Early online date10 Nov 2026
DOIs
Publication statusE-pub ahead of print - 10 Nov 2026

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 13 - Climate Action
    SDG 13 Climate Action

Fingerprint

Dive into the research topics of 'Monitoring and modelling of indoor environmental quality to guide indoor greening applications'. Together they form a unique fingerprint.

Cite this