TY - JOUR
T1 - Reliability of a two-dimensional sock-clad footprint linear measurement method
AU - Nirenberg, Michael S.
AU - Ansert, Elizabeth
AU - Reel, Sarah
N1 - Publisher Copyright:
© 2021 The Chartered Society of Forensic Sciences
Copyright:
Copyright 2021 Elsevier B.V., All rights reserved.
PY - 2021/9/1
Y1 - 2021/9/1
N2 - A two-dimensional linear measurement approach for footprints, herein referred to as the “Reel Method,” has been shown to be valid and reliable when used on bare footprints, however, few measurement approaches have been examined on sock-clad footprints. The present investigation examines the validity and reliability of the Reel Method as a two-dimensional linear measurement approach for use on sock-clad footprints. A walking, mid-gait footprint was collected from 30 volunteer participants using the Identicator Inkless Shoe Print Model LE 25P system. The width of the ball of the foot, calcaneal width, and distance from the most posterior aspect of the heel to the most distal aspect of the first toe were each measured and compared between and within three raters. The statistical analysis demonstrated high reliability of the Reel Method among these three raters. The data were found to be normally distributed, and measurements were consistent between and within raters. 95% Intraclass Correlation coefficients, 95% Bland-Altman Limits of Agreement and 95% Standard Error of Measurement determined high statistical agreement between and within raters, demonstrating that the Reel Method is reliable and thus valid for the linear measurement of sock-clad footprints.
AB - A two-dimensional linear measurement approach for footprints, herein referred to as the “Reel Method,” has been shown to be valid and reliable when used on bare footprints, however, few measurement approaches have been examined on sock-clad footprints. The present investigation examines the validity and reliability of the Reel Method as a two-dimensional linear measurement approach for use on sock-clad footprints. A walking, mid-gait footprint was collected from 30 volunteer participants using the Identicator Inkless Shoe Print Model LE 25P system. The width of the ball of the foot, calcaneal width, and distance from the most posterior aspect of the heel to the most distal aspect of the first toe were each measured and compared between and within three raters. The statistical analysis demonstrated high reliability of the Reel Method among these three raters. The data were found to be normally distributed, and measurements were consistent between and within raters. 95% Intraclass Correlation coefficients, 95% Bland-Altman Limits of Agreement and 95% Standard Error of Measurement determined high statistical agreement between and within raters, demonstrating that the Reel Method is reliable and thus valid for the linear measurement of sock-clad footprints.
KW - Footprint
KW - Forensic, Reel method
KW - Measurement
KW - Sock-clad footprint
UR - http://www.scopus.com/inward/record.url?scp=85112252976&partnerID=8YFLogxK
U2 - 10.1016/j.scijus.2021.07.007
DO - 10.1016/j.scijus.2021.07.007
M3 - Article
AN - SCOPUS:85112252976
VL - 61
SP - 649
EP - 656
JO - Science and Justice - Journal of the Forensic Science Society
JF - Science and Justice - Journal of the Forensic Science Society
SN - 1355-0306
IS - 5
ER -