The use of CMM techniques to assess the functionality of total knee replacements

P. Bills, L. Blunt, C. Hardaker

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Wear analysis of total joint replacements is an important means in determining failure mechanisms and improving longevity of these devices. In developing such joints the industry standard wear measurement methodology is to use gravimetric methods only. This method can introduce significant errors to the wear measurement when there is material transfer from the metal component to the plastic component or when trying to consider the effects of fluid uptake into the ultra high molecular weight polyethylene (UHMWPE) counterface. It is also impossible to accurately measure a cemented component throughout a test by using purely gravimetric means for similar reasons. Consequently there is a need for an alternative measurement method that accounts for this factor. The purpose of the present study is to establish the effectiveness of the CMM technique for assessing volumetric material loss during simulated life testing of a replacement knee joint. In this study a standard design total knee replacement joint was chosen and samples were tested in a knee simulator to simulate 5 years worth of wear from walking. At the start of the test the bearing surface was scanned and digitised into CAD data, by use of a CMM, to use as a baseline comparator. Further measurements were then taken at various points throughout the test and compared with simultaneously taken gravimetric data. The implications of the results are discussed here in terms of assessment of joint functionality and development of standardised CMM based product standards.

LanguageEnglish
JournalVDI Berichte
Issue number1860
Publication statusPublished - 7 Dec 2004

Fingerprint

Knee prostheses
Coordinate measuring machines
Wear of materials
Bearings (structural)
Ultrahigh molecular weight polyethylenes
Computer aided design
Simulators
Metals
Plastics
Fluids
Testing
Industry

Cite this

@article{19f470daeafe4a8eb17d14823c601dce,
title = "The use of CMM techniques to assess the functionality of total knee replacements",
abstract = "Wear analysis of total joint replacements is an important means in determining failure mechanisms and improving longevity of these devices. In developing such joints the industry standard wear measurement methodology is to use gravimetric methods only. This method can introduce significant errors to the wear measurement when there is material transfer from the metal component to the plastic component or when trying to consider the effects of fluid uptake into the ultra high molecular weight polyethylene (UHMWPE) counterface. It is also impossible to accurately measure a cemented component throughout a test by using purely gravimetric means for similar reasons. Consequently there is a need for an alternative measurement method that accounts for this factor. The purpose of the present study is to establish the effectiveness of the CMM technique for assessing volumetric material loss during simulated life testing of a replacement knee joint. In this study a standard design total knee replacement joint was chosen and samples were tested in a knee simulator to simulate 5 years worth of wear from walking. At the start of the test the bearing surface was scanned and digitised into CAD data, by use of a CMM, to use as a baseline comparator. Further measurements were then taken at various points throughout the test and compared with simultaneously taken gravimetric data. The implications of the results are discussed here in terms of assessment of joint functionality and development of standardised CMM based product standards.",
author = "P. Bills and L. Blunt and C. Hardaker",
year = "2004",
month = "12",
day = "7",
language = "English",
journal = "VDI-Berichte",
issn = "1434-1948",
publisher = "Wiley-VCH Verlag",
number = "1860",

}

The use of CMM techniques to assess the functionality of total knee replacements. / Bills, P.; Blunt, L.; Hardaker, C.

In: VDI Berichte, No. 1860, 07.12.2004.

Research output: Contribution to journalArticle

TY - JOUR

T1 - The use of CMM techniques to assess the functionality of total knee replacements

AU - Bills, P.

AU - Blunt, L.

AU - Hardaker, C.

PY - 2004/12/7

Y1 - 2004/12/7

N2 - Wear analysis of total joint replacements is an important means in determining failure mechanisms and improving longevity of these devices. In developing such joints the industry standard wear measurement methodology is to use gravimetric methods only. This method can introduce significant errors to the wear measurement when there is material transfer from the metal component to the plastic component or when trying to consider the effects of fluid uptake into the ultra high molecular weight polyethylene (UHMWPE) counterface. It is also impossible to accurately measure a cemented component throughout a test by using purely gravimetric means for similar reasons. Consequently there is a need for an alternative measurement method that accounts for this factor. The purpose of the present study is to establish the effectiveness of the CMM technique for assessing volumetric material loss during simulated life testing of a replacement knee joint. In this study a standard design total knee replacement joint was chosen and samples were tested in a knee simulator to simulate 5 years worth of wear from walking. At the start of the test the bearing surface was scanned and digitised into CAD data, by use of a CMM, to use as a baseline comparator. Further measurements were then taken at various points throughout the test and compared with simultaneously taken gravimetric data. The implications of the results are discussed here in terms of assessment of joint functionality and development of standardised CMM based product standards.

AB - Wear analysis of total joint replacements is an important means in determining failure mechanisms and improving longevity of these devices. In developing such joints the industry standard wear measurement methodology is to use gravimetric methods only. This method can introduce significant errors to the wear measurement when there is material transfer from the metal component to the plastic component or when trying to consider the effects of fluid uptake into the ultra high molecular weight polyethylene (UHMWPE) counterface. It is also impossible to accurately measure a cemented component throughout a test by using purely gravimetric means for similar reasons. Consequently there is a need for an alternative measurement method that accounts for this factor. The purpose of the present study is to establish the effectiveness of the CMM technique for assessing volumetric material loss during simulated life testing of a replacement knee joint. In this study a standard design total knee replacement joint was chosen and samples were tested in a knee simulator to simulate 5 years worth of wear from walking. At the start of the test the bearing surface was scanned and digitised into CAD data, by use of a CMM, to use as a baseline comparator. Further measurements were then taken at various points throughout the test and compared with simultaneously taken gravimetric data. The implications of the results are discussed here in terms of assessment of joint functionality and development of standardised CMM based product standards.

UR - http://www.scopus.com/inward/record.url?scp=19744381791&partnerID=8YFLogxK

M3 - Article

JO - VDI-Berichte

T2 - VDI-Berichte

JF - VDI-Berichte

SN - 1434-1948

IS - 1860

ER -